accessory:add-on_boards:xu4_cloudshell2:firmware_upgrade [2017/11/21 11:39]
neal
accessory:add-on_boards:xu4_cloudshell2:firmware_upgrade [2018/06/12 10:46] (current)
neal [How to upgrade F/W with JSM561 under CloudShell2]
Line 4: Line 4:
  
 ===== Revision history ===== ===== Revision history =====
 +(You can see the current Firmware version using [[accessory:​add-on_boards:​xu4_cloudshell2:​firmware_upgrade#​example_5_show_version_information_of_bridge_chip_firmware|JMS561FwUpdate]] command tool)
  
- +|  #  |  DATE       ​| ​ F/W Base             ​| ​ Release F/W version\\ (Using tool RAID Manager) ​          |  The F/W release note                                                                        |  Issues ​                                                                                                                                                                                                                                                                                                                                                       | 
-|  #  |  DATE       ​| ​ F/W Base             ​| ​ Release F/W version ​                     |  The F/W release note                                                                        |  Issues ​                                                                                                                                                                                                                                                                                                                                                       | +|  0  |  2016.9.19 ​ |  JMS561 Standard F/W  |  <color #​ed1c24>​JMS561b_v8.0.3.7</​color>​\\ (N/A)           |                                                                                              | <color #​ed1c24>​1</​color>​. SATA device error and disconnect, when requesting \\     the S.M.A.R.T information.(Especially with the option "-l devstat"​ on the second disk)\\ <color #​ed1c24>​2</​color>​. No Raid manager tool for JMS56X controller console version. ​ | 
-|  0  |  2016.9.19 ​ |  JMS561 Standard F/W  |  <color #​ed1c24>​JMS561b_v8.0.3.7</​color> ​ |                                                                                              | <color #​ed1c24>​1</​color>​. SATA device error and disconnect, when requesting \\     the S.M.A.R.T information.\\ <color #​ed1c24>​2</​color>​. No Raid manager tool for JMS56X controller console version.\\ <color #​ed1c24>​3</​color>​. smartctl command getting the same serial number and same smart \\      information even if two SATA devices plug on JMS561.  | +|  1  |  2017.6.16 ​ |  JMS561 Standard F/W  |  <color #​ed1c24>​v158.001.000.001</​color>​\\ (V9E.01.00.01) ​ | 1. First release\\ 2. Support USB BOT mode only\\ 3. Support JMS561 RAID AP under Linux O/S  | <color #ed1c24>3</​color>​. Not support USB Attached SCSI(UAS) ​                                                                                                                                                                                                                                                                                                  | 
-|  1  |  2017.6.16 ​ |  JMS561 Standard F/W  |  <color #​ed1c24>​v158.001.000.001</​color> ​ | 1. First release\\ 2. Support USB BOT mode only\\ 3. Support JMS561 RAID AP under Linux O/S  | <color #ed1c24>4</​color>​. Not support USB Attached SCSI(UAS) ​                                                                                                                                                                                                                                                                                                  | +|  2  |  2017.7.28 ​ |  v158.001.000.001 ​    ​| ​ <color #​ed1c24>​v158.001.000.002</​color>​\\ (V9E.01.00.01) ​ | 1. SMART log display base on WD My Book Duo\\ JMS561 behavior. ​                              | <color #ed1c24>3</​color>​. Not support USB Attached SCSI(UAS)\\ <color #​ed1c24>​4</​color>​. smartctl command getting the same serial number and same smart \\      information even if two SATA devices plug on JMS561. ​                                                                                                                                                                                                                                                                                              
-|  2  |  2017.7.28 ​ |  v158.001.000.001 ​    ​| ​ <color #​ed1c24>​v158.001.000.002</​color> ​ | 1. SMART log display base on WD My Book Duo\\ JMS561 behavior. ​                              | <color #ed1c24>4</​color>​. Not support USB Attached SCSI(UAS) ​                                                                                                                                                                                                                                                                                                  ​+|  3  |  2017.8.3 ​  ​| ​ v158.001.000.002 ​    ​| ​ <color #​ed1c24>​v158.001.000.003</​color>​\\ (V9E.01.00.01) ​ | 1. Fix S.M.A.R.T log display issue @ JMS561 SATA Port 1                                      | <color #ed1c24>3</​color>​. Not support USB Attached SCSI(UAS)\\ <color #​ed1c24>​4</​color>​. smartctl command getting the same serial number and same smart \\      information even if two SATA devices plug on JMS561.
-|  3  |  2017.8.3 ​  ​| ​ v158.001.000.002 ​    ​| ​ <color #​ed1c24>​v158.001.000.003</​color> ​ | 1. Fix S.M.A.R.T log display issue @ JMS561 SATA Port 1                                      | <color #ed1c24>4</​color>​. Not support USB Attached SCSI(UAS) ​                                                                                                                                                                                                                                                                                                  ​+|  4  |  2017.9.6 ​  ​| ​ v158.001.000.003 ​    ​| ​ <color #​ed1c24>​v158.001.000.004</​color>​\\ (V9E.01.00.04) ​ | 1. Support USB UAS Mode                                                                      | <color #​ed1c24>​5</​color>​. The issue number 1 cannot fix.\\ Jmicron said that there is UAS(USB3.0 host driver) issue of both OS\\ Linux and Windows.\\ <color #​ed1c24>​6</​color>​. The issue number ​cannot fix. Jmicron said it's H/W limitations(JMS561 is RAID manager chip)                                                                                ​|
-|  4  |  2017.9.6 ​  ​| ​ v158.001.000.003 ​    ​| ​ <color #​ed1c24>​v158.001.000.004</​color> ​ | 1. Support USB UAS Mode                                                                      | <color #​ed1c24>​5</​color>​. The issue number 1 cannot fix.\\ Jmicron said that there is UAS(USB3.0 host driver) issue of both OS\\ Linux and Windows.\\ <color #​ed1c24>​6</​color>​. The issue number ​cannot fix. Jmicron said it's H/W limitations. ​                                                                                                             |+
  
 ===== How to upgrade F/W with JSM561 under Windows===== ===== How to upgrade F/W with JSM561 under Windows=====
Line 63: Line 63:
 {{:​accessory:​add-on_boards:​xu4_cloudshell2:​cloudshell2_fw_done.png?​600|}} {{:​accessory:​add-on_boards:​xu4_cloudshell2:​cloudshell2_fw_done.png?​600|}}
  
-===== How to upgrade F/W with JSM561 under XU4 =====+===== How to upgrade F/W with JSM561 under CloudShell2 ​=====
 <WRAP round important 40%> <WRAP round important 40%>
 <fs large> <fs large>
 System power ON and OFF required to apply!!!\\ System power ON and OFF required to apply!!!\\
-You have to pull out your power plug on CloudShell2 ​after F/W upgrade.\\ +After F/W upgrade, you have to system off safely and pull out power plug your CloudShell2.\\ 
-And then connect it again.+And then connect it(Power on) again.
 </fs> </fs>
 </​WRAP>​ </​WRAP>​
Line 83: Line 83:
 {{ :​accessory:​add-on_boards:​xu4_cloudshell2:​jms561_fw_updater_onxu4.tgz |}} \\ {{ :​accessory:​add-on_boards:​xu4_cloudshell2:​jms561_fw_updater_onxu4.tgz |}} \\
 <color #​ed1c24>​Note:​ Please make sure that the device path is correct.</​color>​ <color #​ed1c24>​Note:​ Please make sure that the device path is correct.</​color>​
 +
 +== Example 0. After upgrading the firmware this procedure must be followed. ==
 +<code (bash)>
 +Safely shutdown the device either through the GUI or by typing "sudo shutdown"​ in an ssh terminal.
 +Pull the power plug then wait two seconds.
 +Plug the device back in. When the device boots it will be using the updated firmware.
 +</​code>​
  
 == Example 1. shows version information of software. == == Example 1. shows version information of software. ==
Line 179: Line 186:
 If you want to see JSM561 f/w version, you should use tool JMMassProd2_v1_16_14_1.exe under Windows.\\ If you want to see JSM561 f/w version, you should use tool JMMassProd2_v1_16_14_1.exe under Windows.\\
 Or use raid manager(raidmgr_static) console version under CloudShell2 if you have JSM561 f/w is higher than JMS561b_v8.0.3.7.\\ Or use raid manager(raidmgr_static) console version under CloudShell2 if you have JSM561 f/w is higher than JMS561b_v8.0.3.7.\\
 +Add one thing to check current f/w version under CloudShell2 is that JMS561FwUpdate utility.\\
 +(Refer Example 5. Show version information of bridge chip firmware). \\
 </fs> </fs>