accessory:power_supply_battery:smartpower3:old_protocol

Old Logging Protocol

If you use firmware Dec 14 2021 or above on your SmartPower3, please refer to the latest protocol.
logging_protocol

Total size : (75) () : size of character
Time Input Power Channel 0 Output Channel 1 Output Linefeeds
(10) (1) (5) (1) (4) (1) (5) (1) (1) (1) (5) (1) (4) (1) (5) (1) (1) (1) (2) (1) (5) (1) (4) (1) (5) (1) (1) (1) (2) (2)
time stamp(ms),volt(mV),ampere(mA),watt(mW),on/off,volt(mV),ampere(mA),watt(mW),on/off,interrupts,volt(mV),ampere(mA),watt(mW),on/off,interrupts '\n\r'

Interrupts

Bit Function Notes
0 Overvoltage protection
1 Constant current function
2 Short-circuit protection
3 Power-on
4 Watchdog
5 Overtemperature protection Junction temperatrue 165 Celsius
6 Overtemperature warning Junction temperature 145 Celsius
7 Inductor peak current protection

For example,

0001552821,15250,0398,00000,0,11966,0163,01954,1,0,04991,0623,03108,1,0
  • accessory/power_supply_battery/smartpower3/old_protocol.txt
  • Last modified: 2021/12/21 15:06
  • by john1117